Structural support and seismic anchorage for data centers and mission-critical facilities — generator platforms, rooftop dunnage, and equipment supports engineered to protect uptime, stamped by a licensed P.E.
Request a QuotePlatforms, frames, and dunnage for generators, chillers, and critical gear.
Rooftop support steel and curbs that spread loads to the structure.
Anchorage and bracing for Ip=1.5 equipment to ASCE 7 Chapter 13.
Platforms, day-tank, and pipe supports for standby power.
Trapeze and rack supports engineered and seismically braced.
Support and isolation for CRAC/CRAH, chillers, and cooling towers.
Equipment mezzanines, catwalks, and maintenance access to code.
Isolation and snubber coordination for rotating equipment.
Stamped anchorage calculations and shop-ready support drawings.
From generator platforms to the last cable-tray support — engineered and anchored so critical equipment stays put and stays running.
Support steel and seismic anchorage that protects uptime.
NEBS-informed racks, supports, and restraint for critical gear.
Equipment supports for facilities with strict continuity requirements.
Hardened, code-compliant supports for critical operations.
Standby generation, switchgear, and substation equipment supports.
Mission-critical control and process equipment support and anchorage.
Mission-critical equipment carries an importance factor of Ip=1.5 — it has to keep working through a seismic event. We deliver the stamped anchorage and support steel that makes that happen.
Request a QuoteCritical facilities use an importance factor (Ip=1.5) under ASCE 7 Chapter 13, so equipment and its supports must stay anchored and operational through a seismic event. We deliver stamped anchorage and bracing calculations.
Yes — rooftop support steel, curbs, and dunnage sized to spread unit and maintenance loads into the roof structure, with roofing coordination.
Yes — generator platforms, day-tank and bulk fuel supports, and associated pipe supports, anchored for seismic and operating loads.
Yes — stamped anchorage calculations and drawings ready for the AHJ, special inspection, and commissioning.
Yes — trapeze and rack supports for tray, busway, and conduit, plus supports and seismic restraint for CRAC/CRAH, chillers, and cooling towers.
Tell us the equipment, the site seismicity, and the uptime requirement — we’ll engineer and stamp the supports and anchorage.
Request a Quote
Let’s build together. Get in touch today for a free quote or to learn how we can support your next project.
Request a Quote
Structural support and seismic anchorage for data centers and mission-critical facilities — generator platforms, rooftop dunnage, and equipment supports engineered to protect uptime, stamped by a licensed P.E.
Request a QuoteFrom generator platforms to the last cable-tray support — engineered and anchored so critical equipment stays put and stays running.
Support steel and seismic anchorage that protects uptime.
NEBS-informed racks, supports, and restraint for critical gear.
Equipment supports for facilities with strict continuity requirements.
Hardened, code-compliant supports for critical operations.
Standby generation, switchgear, and substation equipment supports.
Mission-critical control and process equipment support and anchorage.
Mission-critical equipment carries an importance factor of Ip=1.5 — it has to keep working through a seismic event. We deliver the stamped anchorage and support steel that makes that happen.
Critical facilities use an importance factor (Ip=1.5) under ASCE 7 Chapter 13, so equipment and its supports must stay anchored and operational through a seismic event. We deliver stamped anchorage and bracing calculations.
Yes — rooftop support steel, curbs, and dunnage sized to spread unit and maintenance loads into the roof structure, with roofing coordination.
Yes — generator platforms, day-tank and bulk fuel supports, and associated pipe supports, anchored for seismic and operating loads.
Yes — stamped anchorage calculations and drawings ready for the AHJ, special inspection, and commissioning.
Yes — trapeze and rack supports for tray, busway, and conduit, plus supports and seismic restraint for CRAC/CRAH, chillers, and cooling towers.
Tell us the equipment, the site seismicity, and the uptime requirement — we’ll engineer and stamp the supports and anchorage.
Request a Quote